MDC08B - DC Distribution
Mersen’s MDC battery module fuse is designed and tested for the protection of battery modules. The MDC08B series provides back-up protection to the battery module during shipping, transportation, and handling of the module.
The MDC08B Series incorporates proven fuse technologies which provides optimal current limitation while achieving maximum performance. The battery module fuse is designed to provide back-up protection while maintaining a slow melting time. It is important for a battery module fuse to have a slower melting time to ensure coordination with upstream fuses can be achieved. This allows battery module manufactures the ease of mind that the battery is protected during shipping, handling, and transportation and once installed within a system, that the traditional fast-acting upstream fuses will coordinate with the battery.
Mersen’s MDC battery module fuse is designed and tested for the protection of battery modules. The MDC08B series provides back-up protection to the battery module during shipping, transportation, and handling of the module.
The MDC08B Series incorporates proven fuse technologies which provides optimal current limitation while achieving maximum performance. The battery module fuse is designed to provide back-up protection while maintaining a slow melting time. It is important for a battery module fuse to have a slower melting time to ensure coordination with upstream fuses can be achieved. This allows battery module manufactures the ease of mind that the battery is protected during shipping, handling, and transportation and once installed within a system, that the traditional fast-acting upstream fuses will coordinate with the battery.
Product data sheets
- DS-MDC08B-DC-Distribution-Fuse-Mersen-EN
pdf - 1.63 MB
Key features & benefits
Designed for DC applications
Low watt losses
High cycling performance
Low & high current interrupting capability
Ultra compact size
Applications
Battery modules protection
Stationary DC systems
Battery systems
Voltage Range | 80VAC, 80VDC |
Amperage Range | 35 to 750A |
Speed/Characteristic | Fast-Acting |
UL Category Code | JFHR2 |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853610 |
UL File Number | File E60314 |
Reference Finder
Scroll
Item number | Ampere rating Sort descending | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
MDC08B100B See product
|
100A | - | - | No | 0.0181kg |
MDC08B125B See product
|
125A | - | - | No | 0.0181kg |
MDC08B130B See product
|
130A | - | - | No | 0.0181kg |
MDC08B150B See product
|
150A | - | - | No | 0.0181kg |
MDC08B175B See product
|
175A | - | - | No | 0.0181kg |
MDC08B200B See product
|
200A | - | - | No | 0.0181kg |
MDC08B225B See product
|
225A | - | - | No | 0.0181kg |
MDC08B250B See product
|
250A | - | - | No | 0.0181kg |
MDC08B275B See product
|
275A | - | - | No | 0.0181kg |
MDC08B300B See product
|
300A | - | - | No | 0.0181kg |