Back
Where to buy Contact us
PHP-LABCMV223-MSL

MULTIVERT® 800A, 1260A , Double Fuse Switch Disconnector Size 2 and 3

Approvals & Standards
IEC/EN 60 947-3
For NH-fuse links size 2 and 3 in accordance with IEC/EN 60 269-2, VDE 0636-2

MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® double vertical fuse switch disconnectors are for installation on to 185mm bus bar systems. Available designs are MULTIVERT® 800A (2 x 400A and MULTIVERT® 1260A (2x 630A). They are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2:400A and size 3: 630A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.

MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® double vertical fuse switch disconnectors are for installation on to 185mm bus bar systems. Available designs are MULTIVERT® 800A (2 x 400A and MULTIVERT® 1260A (2x 630A). They are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2:400A and size 3: 630A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.

Key features & benefits

  • NH-double vertical fuse switch disconnector size 2, 800 A ( 2 x 400 A)

  • NH-double vertical fuse switch disconnector size 3, 1260 A ( 2 x 630 A)

  • For NH-fuse links in accordance with IEC/EN 60 269-2, VDE 0636-2

  • Installation on to 185mm bus bar system

  • Suitable for top/bottom cable terminal connections

  • Triple pole and single pole switching

  • Multiple cable termination - design with 3 or 4 cables/pole

  • Safe on load connection/disconnection in accordance with IEC 60947-3

Applications

  • Transformer substations

  • Switch boards for industrial applications

  • Residential and industrial distribution units

  • Cable distribution cabinets

Technical Specifications
Frequency (Hz) 50 ... 60 Hz
Short Circuit Current Rating (SCCR) 18kA@Ue=AC500V;Ie=2 x 400A/28kA@Ue=AC500V;Ie=2 x 630A
CE Conformity Yes
Reach Compliant Yes
Degree of Protection (IP) IP20

Reference Finder

8 references in this series

Scroll

Item number Fuse size Number of poles Product weight
S1023125 - 1.500.000 See product
3 2 x 3-Pole 13.3kg
T1023126 - 1.500.004 See product
3 2 x 3-Pole 13.8kg
V1023127 - 1.550.000 See product
3 2 x 3-Pole 13.3kg
W1023128 - 1.550.004 See product
3 2 x 3-Pole 13.8kg
W1023266 - 1.400.000 See product
2 2 x 3-Pole 11.6kg
X1023267 - 1.400.004 See product
2 2 x 3-Pole 12.12kg
Y1023268 - 1.450.000 See product
2 2 x 3-Pole 11.9kg
Z1023269 - 1.450.004 See product
2 2 x 3-Pole 12.3kg
Back to top