Back
Where to buy Contact us
PHP-LFBCS6-MSL

NH fuse-links gG 690VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 425 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Sort ascending Indication System Product weight
D229704 - NH000GG69V2-1 See product
2A NH000 - Yes 0.14kg
E229705 - NH000GG69V4-1 See product
4A NH000 - Yes 0.14kg
F229706 - NH000GG69V6-1 See product
6A NH000 - Yes 0.14kg
F229752 - NH1GG69V200-1 See product
200A NH1 - Yes 0.42kg
T229764 - NH2GG69V200-1 See product
200A NH2 - Yes 0.43kg
G229753 - NH1GG69V224-1 See product
224A NH1 - Yes 0.42kg
V229765 - NH2GG69V224-1 See product
224A NH2 - Yes 0.43kg
D233729 - NH2GG69V250-1 See product
250A NH2 - Yes 0.64kg
X229767 - NH2GG69V300-1 See product
300A NH2 - Yes 0.64kg
C229772 - NH3GG69V315-1 See product
315A NH3 - Yes 0.65kg
Back to top