Back
Where to buy Contact us
PHP-LFBCS6-MSL

NH fuse-links gG 690VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 425 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Sort descending Clearing I2t At Rated Voltage Indication System Product weight
P229737 - NH0GG69V100-1 See product
100A NH0 - Yes 0.25kg
Q229738 - NH0GG69V125-1 See product
125A NH0 - Yes 0.25kg
R229739 - NH0GG69V160-1 See product
160A NH0 - Yes 0.25kg
M229735 - NH0GG69V63-1 See product
63A NH0 - Yes 0.25kg
N229736 - NH0GG69V80-1 See product
80A NH0 - Yes 0.25kg
L229734 - NH0GG69V50-1 See product
50A NH0 - Yes 0.25kg
Z229723 - NH00GG69V80-1 See product
80A NH00 - Yes 0.2kg
A229724 - NH00GG69V100-1 See product
100A NH00 - Yes 0.2kg
B229725 - NH00GG69V125-1 See product
125A NH00 - Yes 0.2kg
Y229722 - NH00GG69V63-1 See product
63A NH00 - Yes 0.2kg
Back to top