MEV55C12 - MEV55C12
EVpack 550VDC UL 12A Pouvoir de coupure max. DC: 20 kA @ 550 V L/R ≤ 1 ms à machoires
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack 550VDC UL 12A Pouvoir de coupure max. DC: 20 kA @ 550 V L/R ≤ 1 ms à machoires
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Fiche produits
Drawings
pdf - 118.93 Ko
STEP - 119.23 Ko
Compliances
pdf - 142.27 Ko
pdf - 284.29 Ko
pdf - 183.16 Ko
pdf - 284.29 Ko
Numéro d'article | MEV55C12 |
Numéro de catalogue | MEV55C12 |
Description | EVpack 550VDC UL 12A Pouvoir de coupure max. DC: 20 kA @ 550 V L/R ≤ 1 ms à machoires |
Code EAN / UPC | 0782001483036 |
Tension nominale DC UL | 550 V |
Courant assigné | 12 A |
Conforme à ROHS | Oui |
AC ou DC | DC |
Montage | Clip |
Pouvoir de coupure minimal (MBC) | 24 A |
Max. Rated Breaking Capacity DC | 20 kA @ 550 V, L/R ≤ 1 ms |
Connexion / Matériel terminal | Cuivre étamé |
Type de Connexion / Borne | à machoires |
Diamètre du produit | 10.3 mm |
Longueur du produit | 38 mm |
Quantité du pack de vente | 10 EA |
Poids du pack de vente | 0.075 kg |
Largeur du pack de vente | 0.9 mm |
Longueur du pack de vente | 1.6 mm |
Hauteur du pack de vente | 2.1 mm |
Groupe de produits | EV and Battery Protection Fuses |
Poids du produit | 0.0075 kg |
Dissipation thermique à la valeur de courant intermédiaire | 0.47 W @ 0.5 In |