Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Series
HelioProtection® HP15NH, Photovoltaic fuse-links gPV 1500VDC
Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP15NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on 1XL/2XL/3L sizes having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards.
They are available with plain blades, bolted blades for direct mounting with and without striker.
Read
Series
NH Fuse-links gBat 1000V-1500V DC
Mersen NH gBat fuse series was engineered specifically for protection
of battery systems. They offer full range protection and can protect
very small over currents as well as DC fault current up to 150kA. The
NH gBat fuses serie covers various ratings in 1000VDC with NH1 and
NH2 sizes, and in 1500VDC with NH1XL, NH2XL and NH3L sizes. They are gBat type that comply with new IEC 60269-7 standard for Battery protection. They are available with bolted type blades for
direct mounting, or with plain blades.
Read
Series
7.2 kV DIN Mount Motor
Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized.
DEFINITIONS:
*R-Rating: R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000): An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating
*Back-up Current-Limiting Fuses: A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions
*Continuous Ampere Rating at 40°C: The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection
*Spring-Reinforced Clip MR45 & Spring Ref.# L096472
*Fuse-Holder: SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625
*Note: Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details
Read
Product
A072D1DSR0-13R
Back-Up R-Rated Medium Voltage Fuse 7.2 kV DIN Mount Motor 13R Visual Indicator
Read
Series
5.5kV Bolt-On Mount Transformer Fuses
Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double, triple or quadruple barrels 3 inch diameter (size D) with end mounts designed for bolting directly to equipment bus or terminal pads.
Read
Product
A055B1DAR0-10E
Medium Voltage E-Rated Fuse 5500VAC 10A Bolt-On, Series: DAR0 Visual Indicator Amp-Trap®
Read
Product
A055B1DAR0-15E
Medium Voltage E-Rated Fuse 5500VAC 15A Bolt-On, Series: DAR0 Visual Indicator Amp-Trap®
Read
Product
A055B1DAR0-20E
Medium Voltage E-Rated Fuse 5500VAC 20A Bolt-On, Series: DAR0 Visual Indicator Amp-Trap®
Read
Product
A055B1DAR0-125E
Medium Voltage E-Rated Fuse 5500VAC 125A Bolt-On, Series: DAR0 Visual Indicator Amp-Trap®
Read
Product
A055B1DAR0-150E
Medium Voltage E-Rated Fuse 5500VAC 150A Bolt-On, Series: DAR0 Visual Indicator Amp-Trap®
Read