HelioProtection® DC10HEL , fuse links gPV 10x85 900 to 1200VDC
Mersen DC10HEL photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1200VDC rated DC10HEL, designed for low minimum breaking capacity capabilities of 1.30 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen HelioProtection® fuse line.
Mersen DC10HEL photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1200VDC rated DC10HEL, designed for low minimum breaking capacity capabilities of 1.30 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen HelioProtection® fuse line.
Product data sheets
Brochures and Flyers
- BR-Helioprotection-Mersen-EN
pdf - 12.47 MB
Compliance
- COM-REACH-declaration-0014-DC10-GPV-fuses
pdf - 244.2 KB
- COM-CE-ROHS-declaration-0014-DC10-GPV-fuses
pdf - 130.31 KB
- COM-UKCA-declaration-0014-DC10-GPV-fuses
pdf - 166.04 KB
Key features & benefits
Guaranteed operation at temperature extremes (-30°C to +70°C)
Low fault current interrupting capability
Temperature cycle withstand capability
Durable construction for enhanced system longevity
Industries first UL Listed Solution
Globally accepted
Applications
All photovoltaic applications
PV string/array level protection
Combiner box applications
In-line PV module protection
Inverters
Battery charge controllers
Voltage Range | 900 ... 1200 V DC |
Amperage Range | 8 ... 25 A |
Speed/Characteristic | gPV |
CE Conformity | Yes |
Reach Compliant | Yes |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A1008757 - DC10HEL9C25 See product
|
25A | - | 1680A²s | No | 0.014kg |
D1014188 - DC10HEL12C8 See product
|
8A | - | 210A²s | No | 0.014kg |
T1012017 - DC10HEL12C10 See product
|
10A | - | 520A²s | No | 0.014kg |
X1008754 - DC10HEL12C12,5 See product
|
12.5A | - | 310A²s | No | 0.014kg |
Y1008755 - DC10HEL12C16 See product
|
16A | - | 640A²s | No | 0.014kg |
Z1008756 - DC10HEL12C20 See product
|
20A | - | 1100A²s | No | 0.014kg |