MULTIVERT® 160A/60mm, Size 00, 690VAC, Triple Pole Switching
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 160A 60mm triple pole switching are for installation on to 60 mm bus bar systems. MULTIVERT® 160A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 160A 60mm triple pole switching are for installation on to 60 mm bus bar systems. MULTIVERT® 160A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
Product data sheets
Brochures and Flyers
- BR-Fuse_Switch_Disconnector-Mersen-EN
pdf - 3.71 MB
Compliance
Key features & benefits
Installation on to 60mm bus bar system
bus bar width 20 - 30mm, bus bar thickness 10mm
Design for bottom or top cable terminal connection
Touch protection IP 30 with central cover
Parking position of switch operating cover even with fuse-links inserted
Varieties of cable termination: screw, clamp strap, AlCu clamp, frame clamp, V-terminal
Safe on load connection/disconnection in accordance with IEC 60947-3
Applications
House incoming units
Meter distribution units
Measuring transformer cabinets
Transmitting stations for telecommunications
Residential and industrial distribution units
Cable distribution cabinets
Feeder pillars
Frequency (Hz) | 50 ... 60 Hz |
Short Circuit Current Rating (SCCR) | 120kA@Ue = AC 400 V; Ie = 160 A / 120kA@Ue = AC 500 V; Ie = 160 A / 50kA@Ue = AC 690 V; Ie = 100 A |
CE Conformity | Yes |
Reach Compliant | Yes |
Degree of Protection (IP) | IP30 |
Reference Finder
Scroll
Item number Sort descending | Fuse size | Number of poles | Product weight |
---|---|---|---|
A1023155 - 1.003.140 See product
|
00 | 3-Pole | 1.5kg |
C1023157 - 1.003.307 See product
|
00 | 3-Pole | 1.5kg |
D1023158 - 1.003.308 See product
|
00 | 3-Pole | 1.5kg |
E1002183 - 1.000.909 See product
|
00 | 3-Pole | 1.45kg |
E1023159 - 1.003.309 See product
|
00 | 3-Pole | 1.3kg |
Z1023154 - 1.002.489 See product
|
00 | 3-Pole | 1.3kg |