MEV50A250-25G
Fusible Evpack 500VDC UL 500VDC CEI 250A Taille 25G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Fusible Evpack 500VDC UL 500VDC CEI 250A Taille 25G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Fiche produits
Drawings
pdf - 161.24 Ko
Compliances
pdf - 157.17 Ko
pdf - 157.1 Ko
| Numéro d'article | MEV50A250-25G |
| Description | Fusible Evpack 500VDC UL 500VDC CEI 250A Taille 25G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné |
| Code EAN / UPC | 6972238870226 |
| Tension nominale DC UL | 500 V |
| Tension nominale DC CEI | 500 V |
| Courant assigné | 250 A |
| Conforme à ROHS | Oui |
| AC ou DC | DC |
| Vitesse/Caractéristique | aR |
| Taille du fusible | 25G |
| Montage | Boulonné |
| I2t de fusion | 12800 A²s |
| Max. Time to clear MBC | 0.5 s |
| Max. Rated Breaking Capacity DC | 30 kA @ 500 V, L/R ≤ 2.5ms |
| DC Min. Breaking Capacity (MBC) | 1250 A @ 500 VDC, ≤ 2.5 ms |
| DC Total clearing I2t | 110000 A²s |
| Connexion / Matériel terminal | Cuivre étamé |
| Type de Connexion / Borne | Boulonné |
| Diamètre du produit | 25 mm |
| Longueur du produit | 92 mm |
| Quantité du pack de vente | 12 EA |
| Poids du pack de vente | 0.9 kg |
| Largeur du pack de vente | 271 mm |
| Longueur du pack de vente | 159 mm |
| Hauteur du pack de vente | 90 mm |
| Groupe de produits | EV and Battery Protection Fuses |
| Matériau isolant / corps | GMG |
| Poids du produit | 0.075 kg |
| Dissipation thermique à la valeur de courant intermédiaire | 6.3 W @ 0.5 In |