HelioProtection® HP10NH, Fusibles photovoltaïques gPV 1000VDC
Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP10NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting.
Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP10NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting.
Fiche produits
Brochures et Flyers
- DS-NH-Fuse-Handles-EN
pdf - 804.83 Ko
- BR-Helioprotection-Mersen-FR
pdf - 10.04 Mo
Compliance
Caractéristiques et avantages
Conformes aux normes PV en vigueur dans le monde
Capacité de coupure des faibles courants de défaut
Bonne tenue en cyclage thermique
Technologie robuste pour une logévité accrue
Haute performance et faible perte en Watt
Empreinte environementale réduite
Disponible en deux versions : couteaux pleins et montage direct
Applications
Toutes applications photovoltaïques
Protection des alimentations onduleurs DC
Applications Re-combiner (sub combiner, chaîne, master combiner)
Caractéristiques produit
Amperage Range | 50 ... 250 A |
Vitesse/Caractéristique | gPV |
Conformité CE | Oui |
Conforme à REACH | Oui |
Les références de cette gamme
Scroll
Numéro d'article | Courant assigné | Taille du fusible | I2t total de coupure à tension nominale | Système d'indication | Poids du produit |
---|---|---|---|---|---|
A1028284 - HP10NH1GPV63 Voir le produit
|
63A | NH1 | - | Non | 0.3kg |
B1028285 - HP10NH1GPV80 Voir le produit
|
80A | NH1 | - | Non | 0.3kg |
B1048663 - HP10NH1GPV50B Voir le produit
|
50A | NH1 | - | Non | 0.4kg |
C1028286 - HP10NH1GPV100 Voir le produit
|
100A | NH1 | - | Non | 0.3kg |
C1048664 - HP10NH1GPV63B Voir le produit
|
63A | NH1 | - | Non | 0.4kg |
D1028287 - HP10NH1GPV125 Voir le produit
|
125A | NH1 | - | Non | 0.3kg |
D1048665 - HP10NH1GPV80B Voir le produit
|
80A | NH1 | - | Non | 0.4kg |
E1028288 - HP10NH1GPV160 Voir le produit
|
160A | NH1 | - | Non | 0.3kg |
E1048666 - HP10NH1GPV100B Voir le produit
|
100A | NH1 | - | Non | 0.4kg |
F1048667 - HP10NH1GPV125B Voir le produit
|
125A | NH1 | - | Non | 0.4kg |