En proposant la plus large gamme de produits de protection électrique de l’industrie, nous sommes à même de fournir des solutions au plus grand nombre, des OEM et constructeurs de panneaux et électriciens, directement ou via des distributeurs de matériel électrique.
Product
MEV50A350-30G
Fusible Evpack 500VDC UL 500VDC CEI 350A Taille 30G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read
Product
MEV50A350-38G
Fusible Evpack 500VDC UL 500VDC CEI 350A Taille 38G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read
Product
MEV50A400-30G
Fusible Evpack 500VDC UL 500VDC CEI 400A Taille 30G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read
Product
MEV50A400-38G
Fusible Evpack 500VDC UL 500VDC CEI 400A Taille 38G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read
Product
MEV50A400-45G
Fusible Evpack 500VDC UL 500VDC CEI 400A Taille 45G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read
Product
MEV50A450-38G
Fusible Evpack 500VDC UL 500VDC CEI 450A Taille 38G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read
Product
MEV100A90-4Y
EVpack 1000VDC UL 90A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné M8
Read
Series
MEV50A
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications.
EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry.
The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection.
The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Read
Product
MEV50A100-20G
Fusible Evpack 500VDC UL 500VDC CEI 100A Taille 20G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read
Product
MEV50A100-25G
Fusible Evpack 500VDC UL 500VDC CEI 100A Taille 25G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
Read